Question

Refer to the exhibit! The API needs to be updated using the company-wide standard for the Plan data type. The Object data type has already been published in Anypoint Exchange with the global reference ACME/DataTypes/PlanDataType.raml. What is a valid RAML specification that reuses the Plan data type?

Answer

The correct answer to this question is D.

Explanation

To reuse a data type, it has to be included it in the RAML specification. According to the RAML syntax, data types are included in the block "types", not in "dataTypes", which eliminates answers A and B.

Further on, to include a RAML file, "!included" is used, not "!reference", which leads us to the answer D.